18L Steam Autoclave Sterilizer Stainless Steel Dual Heating Disinfect Equipment for Lab

18L Steam Autoclave Sterilizer Stainless Steel Dual Heating Disinfect Equipment for Lab
  • Sellerpuraecards.com
  • List PriceUS$349.90piece
  • Sale PriceUS$349.90piece
  • ShippingFree Shipping
  • Ratings4,8 (526)

Product Description

Specifications:
Sterilizing Volume18L
Whole SizeAbout 35 x 28 x 45cm
Power220V/50Hz
Output Power2.0KW
Overpressure Auto-discharging0.145-0.165Mpa
Range Of MeasurementMax. 121°C-128°C
PlugAU Plug
MaterialStainless Steel
ColorSilver
Dimensions320x280x260mm

Operation:
Step 1) Place the sterilizer on a flat surface.
Step 2) Open the lid, take out the inner tank of sterilizer (you can see the heating electric tube),
add water to the heating tube above 3.5L, you must add enough water in time to avoid
burning the electric tube due to lacking of water.
Step 3) Put those items need to sterilize into the sterilization room, you should keep gaps between
the items. Do not block steam holes of the safety valve, air releasing valve, and finally
cover the lid, tighten the screws.
Step 4) After the normal operation of the equipment, when the measured temperature reaches
105 degrees, open the air releasing valve to discharge cold air inside the sterilizer. When
the air releasing valve start going out a little hot steam, close the air releasing valve.
Step 5) When the steam pressure reaches 0.142-0.165MPa , the safety valve will start pressure
relief work, in order to maintain a certain pressure.
Step 6) After sterilization, unplug the power cord. 3 minutes later, open the air releasing valve,
when the pressure gauges to zero, open the lid to discharge the remaining air.

Safety Measure and Maintenance
1) This sterilizer is steam pressure vessel so do not impact in using and forbid overpressure. If the
pressure pointer of pressure gauge reaches the 0.165MPa and the safety valve does not exhaust,
it should stop using at once and check up the safety valve.
2) The pointer should be at zero position before usage the pressure gauge, otherwise the gauge has
been failure and it should repair or replace the gauge. The pressure gauge should be regulated
1~2 times per year, ensuring sensitiveness and correctness.
3) Gasket is easy to wear. If it does not wok well, see it whether become aging and hard, then replace
it in time.

Package Included:
1x Steam Sterilizer
1x Power Cord
Note: We do not provide English usage manual.



18L Steam Autoclave Sterilizer Stainless Steel Dual Heating Disinfect Equipment for Lab

18L Steam Autoclave Sterilizer Stainless Steel Dual Heating Disinfect Equipment for Lab

18L Steam Autoclave Sterilizer Stainless Steel Dual Heating Disinfect Equipment for Lab

18L Steam Autoclave Sterilizer Stainless Steel Dual Heating Disinfect Equipment for Lab

18L Steam Autoclave Sterilizer Stainless Steel Dual Heating Disinfect Equipment for Lab

18L Steam Autoclave Sterilizer Stainless Steel Dual Heating Disinfect Equipment for Lab

18L Steam Autoclave Sterilizer Stainless Steel Dual Heating Disinfect Equipment for Lab

18L Steam Autoclave Sterilizer Stainless Steel Dual Heating Disinfect Equipment for Lab

18L Steam Autoclave Sterilizer Stainless Steel Dual Heating Disinfect Equipment for Lab

Similar Products